Procedure for Reading MGIT DST Results
- Read more about Procedure for Reading MGIT DST Results
- Log in to post comments
Procedure for Reading MGIT DST Results
Base Technical Content in text and simple images.
Procedure for Reading MGIT DST Results
Principle of MGIT DST Reading:
Two Mycobacterial Growth Indicator Tubes (MGITs) are inoculated with the test culture. Then, a known concentration of a test drug is added to one of the MGIT tubes (drug-containing tube), and growth is compared with the MGIT tube without the drug (growth control).
Incubation of MGIT DST tubes
Inoculation of PZA Growth Control/Drug-containing Tube
The PZA susceptibility test is recommended for a pure culture of the M. tuberculosis complex.
It is extremely important to perform quality control of drug susceptibility testing periodically.
Inoculation Preparation for Drug-containing Tube (1-2 days)
Label the required number of 7 mL MGIT tubes with lab ID. In addition, label tubes with one of each of the following: GC (Growth Control), drug 1, drug 2 etc.
Preparation and Storage of Second-line Anti-TB Drugs used for DST
Preparation of second-line drug stock: